Call +44 (0)1252 876726

ECM/8 Monitor

Dedicated Channels

ECM/8 Monitor Internals
2 Power sensing channels Detects voltage present Standard
1 Current sensing Detect current within 10% of required level Standard
1 Pulse sensing Detects a pulse when movement has stopped ECM /8
1 Harness protection channel Detects disconnection of the harness Standard
1 Box lid protection channel Detects removal of the ECM enclosure lid Standard
2 Remote Command relays Customer selected ECM /8
3 Spare channels Customer selected Standard

 

Features

Sony Ericsson modem GSM technology GM47 900/1800 MHz standard
Harness 1 metres 7 core multi pin socket ECM /4 & connection box ECM/4
Harness 1 metres 21 core multi pin socket ECM /8 & connection box ECM/8
Current transformer & 4 pole 13 amp relay standard
External Antenna optional
RS 232 port standard
RFID antenna port standard
RFID enabled board on the ECM 8/T standard
Remotely configurable by Mobile Phone or PC optional
Automatic self setup standard
Battery backup standard
Disconnection protected standard
Opening of box protection standard
Expansion board optional
Minimum IP 65 enclosure & connector plugs & sockets standard

 

Specification

Microcontroller PIC18F6620, 64Kbyte program memory, 3840bytes data memory, 2.5MIPS operation
Non-volatile memory 128-byte EEPROM as standard, up to 64Kbyte optional.
Clock Real Time Clock with lithium manganese battery backup, life expectancy > 5 years
Inputs

Current metering to 25A ac, transformer isolated,
Mains supply side monitoring, opto-isolated.
RCD mains supply consumer side monitoring,
Opto-isolated pulse input, max. frequency 4KHz,
24-380V ac/dc. 4 x opto-isolated digital inputs suitable for volt-free transistors, o/c voltage 12-18V, s/c current 2-3.5mA. contacts or o/c.

Outputs 1 x relay, SPNO, 230VAC/30VDC, 5A resistive.
1 x relay, SPCO, 230VAC/30VDC, 5A resistive.
Optional TI S4100 Multi-function RFID Reader Module.
Communications Dual band (900/1800MHz) GSM modem.
RS232 (9.6Kbaud, 8 data bits, no parity, 1 stop bit) for PC comms or reader module.
Electrical supply 230V ±10%, 50/60Hz, 10VA.
Backup supply Rechargeable 8.4V NiMH battery with deep-discharge protection. 5hrs. typical standby operation.
Fusing (external) Mains supply, 125mA, anti-surge (T).
Physical Dimensions –240x160x80 (LWD) Weight - 1 Kg
Environmental Storage & operating -10 to +50ºC.
Housing Connections sealed to IP65.